Does a 10KL Tetra Pak Pasteurizer Need a Booster Pump? My Experience

2 posts / 0 new
Last post
Surendra Yan
Surendra Yan's picture
Does a 10KL Tetra Pak Pasteurizer Need a Booster Pump? My Experience

For our 10KL Tetra Pak pasteurizer, many vendors suggested installing a booster pump. We decided to check our process first before investing.

The Problem:
Our holding pressure was increasing from 1.5 Bar to 2.8 Bar after 10 hours. Everyone thought the plates were choked and a booster pump was needed.

What We Checked:
We use Alfa Laval P16 plates with a 7-meter holding pipe. The plate gap is 3.2mm. The main issue was not the plate design, but the CIP frequency.

The Test:
We did two tests on the same pasteurizer:
Test 1: CIP after 6 hours - Pressure was 1.5 Bar
Test 2: No CIP for 10 hours - Pressure went to 2.8 Bar

The Result:
With 6-hour CIP, we did not need any booster pump. Our plate life became 7 years.

My Learning:
For a 10KL pasteurizer, a proper 6-hour CIP SOP is more important than a booster pump. We saved a Rs 4 Lakh project and power cost.

Conclusion:
If your 10KL pasteurizer needs a booster pump, first check your CIP frequency. You may save lakhs.

What is your CIP frequency in your plant?

Surendra Yan
Surendra Yan's picture
Booster Pump NOT Required - My Final Update with 6-Hour CIP

Thanks for the discussion. Updating my own experience as promised in the article:

For a 10 KLPH Tetra Pak PHE Pasteurizer, as per PMO/FSSAI rule, a booster pump (Sanitary Centrifugal, SS 316, 28 MWC / 2.8 Bar) IS required to keep pasteurized milk pressure higher than raw milk pressure for cross-contamination prevention.

BUT in my plant experience, we found it NOT required if you strictly follow a 6-hour CIP cycle SOP. Fouling causes pressure to rise from 1.5 Bar to 2.8 Bar after 10 hours. If you do CIP every 6 hours, pressure remains stable, plates last up to 7 years, and you save lakhs on oversized booster pump and power.

So my final take: No booster pump needed if your CIP frequency is 6 hours and balance tank head is OK. Full calculation I have shared in my article on Dairy Knowledge Portal.

What is your CIP frequency in your plant?

- Surendra Yan